Chromatography Multiple Choice Questions and Answers
Chromatography Multiple Choice Questions and Answers
1. In Thin layer chromatography, the stationary phase is made of _________ and the mobile phase is made of _________
a) Solid, liquid
b) Liquid, liquid
c) Liquid, gas
d) Solid, gas
Answer: Solid, liquid.
2. Chromatography is a physical method that is used to separate and analyse __________
a) Simple mixtures
b) Complex mixtures
c) Viscous mixtures
d) Metals
Answer: Complex mixtures.
3. In Gas-liquid phase chromatography, the stationary phase is composed of _________ and the mobile phase is made of _________
a) Solid, liquid
b) Liquid, liquid
c) Liquid, gas
d) Solid, gas
Answer: Liquid, gas.
4. In Column chromatography, the stationary phase is made of _________ and the mobile phase is made of _________
a) Solid, liquid
b) Liquid, liquid
c) Liquid, gas
d) Solid, gas
Answer: Solid, liquid.
5. In chromatography, the stationary phase can be ___________ supported on a solid.
a) Solid or liquid
b) Liquid or gas
c) Solid only
d) Liquid only
Answer: Solid or liquid.
6. Base line resolution is achieved when degree of resolution/separation is ______
a) 1
b) 0
c) 0.5
d) 1.5
Answer: 1.5.
7. The time taken by the analyte after sample injection to reach the detector is called _________
a) Dead time
b) Solute migration rate
c) Adjusted retention time
d) Retention time
Answer: Retention time.
8. The time required for a molecule of the mobile phase to pass through the column is called ___________
a) Dead time
b) Solute migration rate
c) Adjusted retention time
d) Retention time
Answer: Dead time.
9. Adjusted retention time is the remaining retention time after subtracting __________ from ___________
a) Solute migration rate and retention time
b) Retention time and solute migration rate
c) Dead time and retention time
d) Retention time and dead time
Answer: Dead time and retention time.
10. Using Chromatogram as detector in Chromatography, a graph is obtained between ____________ and time.
a) Quantity
b) Density
c) Concentration
d) Specific gravity
Answer: Concentration.
11. Adjusted retention volume is the remaining retention volume after subtracting ___________ from _____________
a) Solute migration rate and retention volume
b) Retention volume and solute migration rate
c) Dead volume and retention volume
d) Retention volume and dead volume
Answer: Dead volume and retention volume.
12. In Automatic amino-acid analyzer, the sample containing ___________ of each amino compound is introduced at the top of the ion exchange column.
a) 1 to 10 µmoles
b) 1 to 10 moles
c) 0.05 to 2 moles
d) 0.05 to 2 µmoles
Answer: 0.05 to 2 µmoles.
13. Which of the following is not true about the radial compression column when compared to standard separation column?
a) Internal diameter decreases
b) Overall operating pressure decreases
c) Analysis time decreases
d) Solvent flow increases
Answer: Internal diameter decreases.
14. Which of the following is not true about narrow bore column when compared to standard columns?
a) Internal diameter decreases
b) Volumetric flow decreases
c) Solvent cost is saved
d) Detector response time increases
Answer: Detector response time increases.
15. Which of the following types of liquid chromatography uses immobilized biochemical as a stationary phase?
a) Ion exchange chromatography
b) Exclusion chromatography
c) Affinity chromatography
d) Gel permeation chromatography
Answer: Affinity chromatography.
16. In chromatography, which of the following can the mobile phase be made of?
a) Solid or liquid
b) Liquid or gas
c) Gas only
d) Liquid only
Answer: Liquid or gas.
17. Which of the following cannot be used as an adsorbent in Column adsorption chromatography?
a) Magnesium oxide
b) Silica gel
c) Activated alumina
d) Potassium permanganate
Answer: Potassium permanganate.
18. Which of the following types of chromatography involves the separation of substances in a mixture over a 0.2mm thick layer of an adsorbent?
a) Gas liquid
b) Column
c) Thin layer
d) Paper
Answer: Thin layer.
19. In which type of chromatography, the stationary phase held in a narrow tube and the mobile phase is forced through it under pressure?
a) Column chromatography
b) Planar chromatography
c) Liquid chromatography
d) Gas chromatography
Answer: Column chromatography.
20. Which of the following is the disadvantage of reciprocating pump used in liquid chromatography?
a) Produces pulsed flow
b) Corrosive components
c) Does not have small hold-up value
d) Does not have moderate flow rate
Answer: Produces pulsed flow
21. Which of the following is not a disadvantage of Pneumatic pumps used in liquid chromatography?
a) Pulsed output
b) Dependent on solvent viscosity
c) Dependent on back pressure
d) Inconvenient for solvent gradient elution
Answer: Pulsed output.
22. Which of the following are the practical problems that arise due to the decrease in column diameter?
a) Requirement of large particle size and high pressure drop
b) Requirement of large particle size and low pressure drop
c) Requirement of small particle size and high pressure drop
d) Requirement of small particle size and low pressure drop
Answer: Requirement of small particle size and high pressure drop.
23. Which of the following is not true about the guard column used in liquid chromatography?
a) It filters particles that clog the separation column
b) It extends the lifetime of separation column
c) It allows particles that cause precipitation upon contact with stationary or mobile phase
d) The size of packing varies with the type of protection needed
Answer: It allows particles that cause precipitation upon contact with stationary or mobile phase.
24. Which of the following columns are not used in liquid or high performance liquid chromatography?
a) Analytical column
b) Separation column
c) Guard column
d) Capillary column
Answer: Capillary column.
25. In which of the following type of paper, chromatography does the mobile phase move horizontally over a circular sheet of paper?
a) Ascending paper chromatography
b) Descending paper chromatography
c) Radial paper chromatography
d) Ascending – descending chromatography
Answer: Radial paper chromatography.
26. Liquid chromatography can be performed in which of the following ways?
a) Only in columns
b) Only on plane surfaces
c) Either in columns or on plane surfaces
d) Neither in columns nor on plane surfaces
Answer: Either in columns or on plane surfaces.
27. Gas chromatography can be performed in which of the following ways?
a) Only in columns
b) Only on plane surfaces
c) Either in columns or on plane surfaces
d) Neither in columns nor on plane surfaces
Answer: Only in columns.
28. Which of the following types of chromatography involves the process, where the mobile phase moves through the stationary phase by the influence of gravity or capillary action?
a) Column Chromatography
b) High Pressure Liquid Chromatography
c) Gas Chromatography
d) Planar Chromatography
Answer: Planar Chromatography
29. Which of the following is not a Column-type Liquid chromatography?
a) Gel permeation
b) Ion exchange
c) Liquid-solid
d) Paper
Answer: Paper.
30. What is the drawback that occurs in using ion exchange chromatography on sulphonated polystyrene resin and colourimetry for amino-acid analysis?
a) Less accuracy
b) Low resolution
c) Inconvenient to handle many individual samples
d) Slow in operation
Answer: Inconvenient to handle many individual samples.
31. Which one of the following methods is the most suitable for amino-acid analysis?
a) Gas chromatography
b) Ion exchange chromatography
c) Paper electrophoresis
d) Resin column chromatography
Answer: Resin column chromatography.
32. Which of the following colour reagents are used in Resin column chromatography?
a) Marquis reagent
b) Benedict reagent
c) Ninhydrin
d) Nessler’s reagent
Answer: Nessler’s reagent.
33. Which of the following is not a desired characteristic of pulse dampers or flow smootheners used in liquid chromatography?
a) Easy mobile phase change over
b) Constant flow must be maintained
c) Should be effective at low system pressure
d) Maximal dead volume
Answer: Maximal dead volume.
34. Which of the following will improve the efficiency of the separation process in liquid chromatography?
a) Increase in sample size, increase in column diameter
b) Reduction in sample size, increase in column diameter
c) Increase in sample size, reduction in column diameter
d) Reduction in sample size, reduction in column diameter
Answer: Reduction in sample size, reduction in column diameter.
35. Which of the following amino-acids is measured at a wavelength of 440nm using photometric systems?
a) Proline
b) Alanine
c) Glutamine
d) Valine
Answer: Proline.
36. What is the drawback that occurs in using gas chromatography for amino-acid analysis?
a) Costly
b) Cannot be used for proteins or polypeptides
c) Slow process
d) Complex in operation
Answer: Cannot be used for proteins or polypeptides.
37. Which of the following cannot be analysed using resin column chromatography?
a) Peptides
b) Amines
c) Amino compounds
d) Components which are ninhydrin negative
Answer: Components which are ninhydrin negative.
38. Trapped air in pumps of Automatic amino-acid analyzer is eliminated using which of the following ways?
a) Suction pump
b) De-aerator
c) Overcome naturally by pump pressure
d) Using pulse damper
Answer: De-aerator.
39. Bulk property detectors used in liquid chromatography does not respond to which of the following properties?
a) Refractive index
b) Density
c) Properties of solutes
d) Dielectric constant
Answer: Properties of solutes.
40. Which of the following is not a property of a good detector used in liquid chromatography?
a) Good sensitivity
b) Ability to function in the presence of a large background signal
c) Short response time
d) Volume of detector must be large
Answer: Volume of detector must be large.
41. Which of the following UV absorbance detectors provide a real time spectrum of the component of interest?
a) Continuous wavelength detector
b) Variable wavelength detector
c) Scanning wavelength detector
d) Fixed wavelength detector
Answer: Scanning wavelength detector.
42. Which of the following detectors depend on Snell’s law at the interface between the cell wall and the flowing liquid to deflect the light beam?
a) Electrochemical detectors
b) Fluorescence detectors
c) Refractive index detectors
d) Thermal conductivity detectors
Answer: Refractive index detectors.
43. Refractive index detectors used in liquid chromatography are not based on which of the following processes?
a) Interference
b) Refraction
c) Reflection
d) Absorption
Answer: Absorption.
44. Which of the following detectors can be used for detection of amino acids in protein hydrolyzates by introducing the reagent dansylchloride in the sample?
a) Electrochemical detectors
b) Fluorescence detectors
c) Refractive index detectors
d) Thermal conductivity detectors
Answer: Fluorescence detectors.
45. The reference cell is packed with which of the following in the Adsorption detector used in liquid chromatography?
a) Inactive glass beads
b) Porous glass beads
c) Alumina
d) Silica
Answer: Inactive glass beads.
46. Which of the following is true about Laser detectors used in liquid chromatography?
a) Causes thermal distortion has decreased sensitivity
b) Causes thermal distortion has increased sensitivity
c) Does not cause thermal distortion, has decreased sensitivity
d) Does not cause thermal distortion, has increased sensitivity
Answer: Causes thermal distortion has decreased sensitivity.
47. Which of the following detectors used in liquid chromatography is also called micro-adsorption detector?
a) Electrochemical detectors
b) Fluorescence detectors
c) Refractive index detectors
d) Thermal detectors
Answer: Thermal detectors.
48. In UV-Visible detectors, the cells are not made of which of the following materials?
a) Quartz
b) Teflon
c) Silica
d) KELF
Answer: Silica.
49. Which of the following is not a feature of refractive index type detectors?
a) Higher potential sensitivity
b) Low cost
c) High volume flow rates
d) Easy cell accessibility
Answer: High volume flow rates.
50. Which of the following detectors can detect almost any component?
a) Combining two UV detectors
b) Combining RI and UV detectors
c) Mass detector
d) Laser-based detectors
Answer: Combining RI and UV detectors.
51. Which of the following is not true about High pressure liquid chromatography (HPLC)?
a) It requires high pressure for the separation of the specious
b) There is no need to vaporise the samples
c) It is performed in columns
d) It has high sensitivity
Answer: There is no need to vaporise the samples.
52. Which of the following is not an advantage of Syringe type pumps used in High pressure liquid chromatography?
a) Independent of viscosity
b) Pulse-less flow
c) High pressure capability
d) Unlimited solvent capacity
Answer: Unlimited solvent capacity.
53. Which of the following is not true about solvent programming which is done in high performance liquid chromatography?
a) It provides unequal bandwidths
b) It provides fast overall separation
c) It provides maximum resolution
d) It provides maximum sensitivity
Answer: It provides unequal bandwidths.
54. Which of the following pulse damper takes up some amount of the pulsation energy which is released to provide smooth pressure without pulsations?
a) Flexible bellows or compressible gas passed through tee columns
b) Flexible inert diaphragm
c) Electronic pulse damper
d) Electrical pulse damper
Answer: Flexible bellows or compressible gas passed through tee columns.
55. Which of the following is not a characteristic of the syringe pump used in high pressure liquid chromatography?
a) Pressure capability is high
b) Maintenance is frequent
c) Limited reservoir capability
d) Slight change of flow rate when extremely high pressure compresses the solvent
Answer: Maintenance is frequent.
56. Syringe pumps used in High pressure liquid chromatography are most suitable for which of the following columns?
a) Capillary columns
b) Guard columns
c) Short-fast columns
d) Small bore columns
Answer: Small bore columns.
57. Which of the following cannot be done to reduce ripple in High pressure liquid chromatography?
a) Using bellows
b) Using restrictors
c) Using long nylon tube between pump and column
d) Avoiding the use of the solvent pump
Answer: Avoiding the use of the solvent pump.
58. Which of the following is not true about Hydraulic capacitance flow control system used in HPLC?
a) It can be used only for liquids with low viscosity
b) It is irrespective of solvent compressibility
c) It maintains a constant flow
d) It smoothens high pressure pump pulsations
Answer: It can be used only for liquids with low viscosity
59. Which of the following is not an ideal characteristic of a detector used in gas chromatography?
a) Linear response to the solutes
b) Short response time
c) High reliability
d) Sensitive to the changes in the flow rate of a carrier gas
Answer: Sensitive to the changes in the flow rate of a carrier gas.
60. Which of the following is not a type of detector used in gas chromatography?
a) Argon ionisation detector
b) Thermal conductivity detector
c) UV visible spectrometric detector
d) Electron capture detector
Answer: UV visible spectrometric detector.
61. Which of the following detectors have high sensitivity to all organic compounds?
a) Sulphur chemiluminescense detector
b) Thermionic emission detector
c) Flame ionization detector
d) Argon ionisation detector
Answer: Flame ionization detector.
62. Which of the following is not the advantage of thermal conductivity detector used in gas chromatography?
a) Simple in construction
b) High sensitivity
c) Large linear dynamic range
d) Non-destructive character
Answer: High sensitivity.
63. Which of the following detectors is widely used to detect environmental samples like chlorinated pesticides and polychlorinated biphenyls?
a) Flame ionization detector
b) Thermal conductivity detector
c) Argon ionisation detector
d) Electron capture detector
Answer: Electron capture detector.
64. In which of the following detector is the eluent mixed with hydrogen and burned and then mixed with ozone and its intensity is measured?
a) Sulphur chemiluminescense detector
b) Thermal conductivity detector
c) Flame ionization detector
d) Electron capture detector
Answer: Sulphur chemiluminescense detector.
65. Filter photometer detector is primarily responsive to which of the following compounds/elements?
a) Volatile sulphur or phosphorous compounds
b) Nitrogen
c) Halogen
d) Potassium
Answer: Volatile sulphur or phosphorous compounds.
66. Which of the following detector uses ultraviolet radiation from lamps to produce ionisation of solute molecules?
a) Sulphur chemiluminescense detector
b) Thermal conductivity detector
c) Photo ionization detector
d) Electron capture detector
Answer: Photo ionization detector.
67. Thermionic emission detector used in gas chromatography is most sensitive to which of the following elements?
a) Nitrogen
b) Phosphorous
c) Halogen
d) Carbon
Answer: Phosphorous.
68. Which of the following detectors has a non-volatile bead of rubidium silicate placed above the flame tip?
a) Argon ionisation detector
b) Thermionic emission detector
c) Flame ionization detector
d) Electron capture detector
Answer: Thermionic emission detector.
69. In which of the following detectors, the carrier gas is excited by a radioactive source and the atoms of carrier gas are excited to a metastable state?
a) Argon ionisation detector
b) Thermionic emission detector
c) Flame ionization detector
d) Electron capture detector
Answer: Argon ionisation detector.
70. Which of the following is not used as a heating element in a Thermal conductivity detector?
a) Platinum
b) Gold
c) Graphite
d) Tungsten wire
Answer: Graphite.
71. Gas-solid chromatography is based on which of the following processes?
a) Partition of the analyte between a gaseous mobile phase and a stationary liquid phase
b) Adsorption of gaseous substances on solid surface
c) Ion exchange
d) Large molecules cannot penetrate through the gel
Answer: Adsorption of gaseous substances on solid surface.
72. Which of the following components cannot be retained by gas-liquid columns but can be separated by using gas-solid chromatography?
a) Formaldehyde
b) Hydrogen sulphide
c) Benzene
d) Carbon dioxide
Answer: Hydrogen sulphide.
73. Which of the following is not an advantage of gas-solid chromatography?
a) Increased column life
b) Can be used for separation of rare gases
c) Leads to semi-permanent retention of the analyte
d) Ability to retain some components that cannot be easily retained by other gas chromatography method
Answer: Leads to semi-permanent retention of the analyte.
74. Which of the following columns can be used in Gas-solid chromatography?
a) Open tubular column
b) Analytical column
c) Separation column
d) Guard column
Answer: Open tubular column.
75. Which of the following is not an advantage for the conversion of packed columns into wide bore capillaries?
a) Longer retention times
b) Longer life
c) Higher efficiency
d) Greater inertness
Answer: Longer retention times.
76. Which of the following is not a disadvantage of gas-solid chromatography?
a) Strong retention of polar solutes
b) Lifetime is short
c) Occurrence of catalytic changes
d) Cannot be used for very wide range of components
Answer: Lifetime is short.
77. Which of the following is a special adsorbent used in gas-solid chromatography?
a) Molecular sieves
b) Silica gel
c) Alumina
d) Starch
Answer: Molecular sieves.
78. Which of the following properties of molecular sieves make it ideal for exclusion mechanism of separation?
a) High thermal stability
b) Large inner surface area
c) Variable framework charge
d) Ability to distinguish materials on the basis of their size
Answer: Ability to distinguish materials on the basis of their size.
79. For the separation of which of the following substances, Gas-solid chromatography is being used?
a) Thermally stable organic components
b) Volatile organic components
c) Thermally stable inorganic components
d) Low molecular weight gaseous species
Answer: Low molecular weight gaseous species.
80. Which of the following is not a feature of carrier gas used in gas chromatography?
a) It must be chemically inert
b) It should be suitable for the detector employed
c) It should not be completely pure
d) It should be cheap
Answer: It should not be completely pure.
81. Which of the following is the disadvantage of hydrogen, which can be used as carrier gas in gas chromatography?
a) Dangerous to use
b) Expensive
c) Reduced sensitivity
d) High density
Answer: Dangerous to use.
82. Which of the following is the disadvantage of helium, which can be used as carrier gas in gas chromatography?
a) Dangerous to use
b) Expensive
c) Reduced sensitivity
d) High density
Answer: Expensive.
83. Which of the following is the disadvantage of nitrogen, which can be used as carrier gas in gas chromatography?
a) Dangerous to use
b) Expensive
c) Reduced sensitivity
d) High density
Answer: Reduced sensitivity.
84. In which of the following methods are liquid samples injected into the column in gas chromatography?
a) Gas tight syringe
b) Micro-syringe
c) Rotary sample valve
d) Solid injection syringes
Answer: Micro-syringe.
85. What must be done to the solid samples for it to be introduced into the column without using solid injection syringes in gas chromatography?
a) Introduced in hot-zone of the column
b) Dissolved in volatile liquids
c) Introduced using rotary sample valve
d) Introduced using sampling loops
Answer: Dissolved in volatile liquids.
86. Which of the following is the commonly used support material for the packed column in gas chromatography?
a) Glass
b) Metal
c) Diatomaceous earth
d) Stainless steel
Answer: Diatomaceous earth.
87. Which of the following is the advantage of a straight packed column?
a) It can be packed uniformly
b) It can be repacked easily
c) It is compact
d) It is easier to heat it evenly
Answer: It is compact.
88. Which of the following is the disadvantage of coiled or helical shaped packed chromatographic column?
a) It cannot be packed uniformly
b) It cannot be repacked easily
c) It is not compact
d) It is not easy to heat it evenly
Answer: It cannot be repacked easily.
89. Capillary columns are open tubular columns constructed from which of the following materials?
a) Glass
b) Metal
c) Stainless steel
d) Fused silica
Answer: Fused silica.
90. Which of the following is not a desirable feature of the ovens used in gas chromatography?
a) It must have a fast rate of heating
b) Power consumption should be kept low
c) It must have maximum thermal gradients
d) It should have proper insulation
Answer: It must have maximum thermal gradients.
91. Which of the following is the distance that the solute moves while undergoing one partition?
a) Retention distance
b) Distribution constant
c) Plate height
d) Column packing length
Answer: Plate height.
92. Which of the following conditions will cause the efficiency of the column to increase?
a) Plate number becomes greater, plate height becomes smaller
b) Plate number becomes smaller, plate height becomes smaller
c) Plate number becomes greater, plate height becomes larger
d) Plate number becomes greater, plate height becomes larger
Answer: Plate number becomes greater, plate height becomes smaller.
93. Which of the following is the expression for Eddy diffusion in the column, if ‘γ’ represents obstruction factor, ‘dp’ represents particle diameter, ‘DM’ represents Solute diffusion co-efficient and ‘λ’ represents function for packing uniformity?
a) λ dM
b) 2 γ DM
c) DM γ
d) λ/dM
Answer: λ dM.
94. Which of the following is the expression for longitudinal diffusion in the column, if ‘γ’ represents obstruction factor, ‘dM’ represents particle diameter, ‘DM’ represents Solute diffusion co-efficient and ‘λ’ represents function for packing uniformity?
a) λ dM
b) 2 γ DM
c) DM γ
d) λ/dM
Answer: 2 γ DM.
95. In gas-liquid chromatography, when films are used in the interior of the capillary column, then what is the value of Eddy diffusion?
a) Greater than 1
b) Less than 1
c) Zero
d) Less than zero
Answer: Zero.
96. For an unpacked coated capillary column, the obstruction factor takes which of the following values?
a) 0
b) 0.6
c) 1
d) 1.6
Answer: 1.
97. Which of the following equations give the expression for plate number, N when ‘tR’ is the adjusted retention time and ‘Wb’ is the width at the base of the peak which is equal to 4 standard deviations.
a) 16 tR2/Wb
b) 4 tR2/Wb
c) (4tR/Wb)2
d) 4 (tR/Wb)2
Answer: (4tR/Wb)2.
98. How is the molar concentration of solute in stationary phase related to molar concentration of solute in the mobile phase?
a) Directly proportional
b) Inversely proportional
c) Equal
d) Not related
Answer: Directly proportional.
99. What must be the value of the selectivity factor?
a) Equal to 1
b) Less than 1
c) Greater than 1
d) Greater than 0
Answer: Greater than 1
100. If the value of the distribution constant ‘k’ is one, then what could be inferred about the distribution of solute?
a) Its distribution in stationary phase is greater
b) Its distribution in mobile phase is greater
c) It is equally distributed in stationary and mobile phase
d) It is distributed in a random manner
Answer: It is equally distributed in stationary and mobile phase.
101. Retention volume can be obtained by finding the product of which of the following parameters?
a) Dead time and total porosity
b) Retention time and volumetric flow rate
c) Adjusted retention time and volumetric flow rate
d) Retention time and total porosity.
Answer: Retention time and volumetric flow rate.
102. Which of the following is defined as the ratio of moles of solute in stationary phase to the moles of solute in the mobile phase?
a) Distribution constant
b) Volumetric phase ratio
c) Retention factor
d) Total porosity
Answer: Retention factor.
103. Which of the following is the volume of mobile phase required to make a solute band move from the point of injection through the column to the detector?
a) Dead volume
b) Retention volume
c) Void volume
d) Adjusted retention volume
Answer: Retention volume.
104. Which of the following is the ratio of the interstitial volume of packing to the volume of its total mass?
a) Distribution constant
b) Volumetric phase ratio
c) Retention factor
d) Total porosity
Answer: Total porosity.
105. Which of the following is the ratio of the length of column packing to dead time?
a) Average linear rate of solute migration
b) Average linear rate of mobile migration
c) Relative migration rate
d) Selectivity factor
Answer: Average linear rate of mobile migration.
106. Which of the following is the ratio of a length of column packing to retention time?
a) Average linear rate of solute migration
b) Average linear rate of mobile migration
c) Relative migration rate
d) Selectivity factor
Answer: Average linear rate of solute migration.
107. In older analytical methods, which of the following methods were used to allow movement of the mobile phase?
a) Pumps
b) Pressure
c) Gravity
d) Blowing air into the column
Answer: Gravity
108. Which of the following steps takes place after injection of feed in Column chromatography?
a) Detection of components
b) Separation in the column
c) Elution from the column
d) Collection of eluted component
Answer: Separation in the column.
109. What happens during the ‘elution from the column’ phase in chromatography?
a) Components with greatest affinity elute first
b) Components with least affinity elute first
c) Components elute in a random manner
d) Components elute according to their concentration in the mixture
Answer: Components with least affinity elute first.
110. In chromatogram, the position of peaks on the time axis can be used to determine which of the following?
a) Components of the sample
b) Amount of component in the sample
c) Column efficiency
d) Column resolution
Answer: Components of the sample.
111. In chromatogram, the area under the peak can be used to determine which of the following?
a) Components of the sample
b) Amount of component in the sample
c) Column efficiency
d) Column resolution
Answer: Amount of component in the sample.
112. The stationary phase could be a viscous liquid coated over a surface of solid particles.
a) True
b) False
Answer: True.
113. Components with a strong attraction to the support move more slowly than components with weak attraction.
a) True
b) False
Answer: True.
114. Retention distance is the distance between point of injection and minimum peak in the recorder or computer generated chart.
a) True
b) False
Answer: False.
115. Retention factor is also known as the capacitance factor.
a) True
b) False
Answer: True.
116. It is more difficult to measure the width at half peak height than the base width in the detector output.
a) True
b) False
Answer: False.
117. The solute, while moving in the column is always in equilibrium with both the stationary phase and the mobile phase.
a) True
b) False
Answer: True
118. Sample injection port must be maintained at a temperature at which rapid vapourisation occurs but thermal degradation does not occur.
a) True
b) False
Answer: True.
119. Slow injection of large samples leads to band broadening and loss of resolution.
a) True
b) False
Answer: True.
120. The distribution coefficients of Gas-solid chromatography are greater than that of Gas-liquid chromatography.
a) True
b) False
Answer: True
121. Gas-solid chromatography can be used only for separation of certain low molecular weight gaseous species.
a) True
b) False
Answer: True.
122. Electron capture detector is much less susceptible to contamination when nickel is used instead of tritium.
a) True
b) False
Answer: True.
123. Flame ionisation detector is also known as Katharometer.
a) True
b) False
Answer: False.
124. Gravity feed method for solvent delivery is not used with narrow bore columns packed with fine mesh particles.
a) True
b) False
Answer: True.
125. High pressure liquid chromatography can be performed only in columns.
a) True
b) False
Answer: True.
126. Detector selectivity is more important in Liquid chromatography than in Gas chromatography.
a) True
b) False
Answer: True.
127. Fluorescence detection is less selective than absorption detection.
a) True
b) False
Answer: False.
128. Amino-acids are distinguishable from each other only by one or two atoms in their structure.
a) True
b) False
Answer: True.
129. Resin column chromatography does not involve breaking of bonds in amino-acids.
a) True
b) False
Answer: False
130. Chromatography cannot be used to separate delicate products.
a) True
b) False
Answer: False.
131. Chromatography cannot be used to purify volatile substances.
a) True
b) False
Answer: False.